5 thoughts on “What is the principle of CT?”

  1. CT means the current transformer.

    The "a few ratios" you are talking about: the ratio of the current transformer in the first or secondary rated current, called the rated interoperability ratio of the current transformer: KN = I1N/I2N
    Because the rated current of the coil I1N is standardized, the secondary coil rated current I2N is uniform to 5 (1 or 0.5), so the current intestines rated meter -of -the -sensor rated interaction ratio has also been standardized. Kn can also be approximately represented as the number of turning ratio of the first and secondary coils of the transformer, that is, the number of turns of the first and second coils in KN≈kn = N1/N2.
    The current transformer is actually equivalent to a transformer, which turns large current into small current supply and protection.

  2. What is right upstairs is right. In simple terms, how much is because the current is too large. Leading out for measures and other tasks.
    It as a line is a 100/5 current transformer, that is, when your instrument display is 5A, then the actual current of this line is 100A. If the display is 3A, the actual current of this line is 60A.
    If it is 200/5, when your instrument display is 5A, the actual current is 200A, and so on.

    The secondary current of the current transformer is generally 5A, but there is also 1A, such as a variable ratio of 100/1,
    If your instrument is displayed 1A, then the actual current of the line is actually actual. It has arrived at 100A

  3. The working principle of the CT machine

    CT scanning section is mainly composed of X -ray tube and different numbers of controller, which is used to collect information. The X -ray beam scan the selected level, and its intensity produces corresponding absorption and attenuation due to the interaction of different density tissues. The detector transforms the X -ray signal into a telecommunications signal, and converts it into a number through the modular / d connector (A / D Converter), and enters the computer storage and processing to obtain the CT number of the volume of each unit at this level. Packed into digital matrix (Figure 7-2). These numbers can be stored in Hard Disk, Floppy and Magnetic Tape, MT, and can also be printed with printer. Digital matrix via the number/mold (D/A) converter converted into an image on the monitor, that is, the horizontal image of the layer. The image can be taken on the film with multiple cameras for reading, archive and consultation.

  4. You are talking about the current transformer, which are generally **/5, which means that the current is reduced to 5 ampel in a line -shaped ratio. This is easy to measure.
    How much is calculated? That is, kn算kn = n1/n2
    Sims of similar products and PT, voltage transformer ==

  5. CT imaging principle
    n00:00 / 01: 0870% shortcut keys: Play / suspend ESC: exit full screen ↑: increase volume 10% ↓: reduced volume decrease by 10% →: single fast forward 5 seconds studio Here you can drag no longer appear in the player settings to reopen the small window shortcut key description